search help
Back Next Glossary All Topics
Probe Sequence
index previous question next question
What is the difference between the BLAST algorithm and the alignment algorithm used by the Probe Match tool?

Alignments by the Probe Match tool produce positive results only if every base in a probe sequence matches perfectly (that is, the aligned bases are identical) with those in the query (input) sequence without any gaps in the query sequence. This algorithm is different from the BLAST algorithm, because the BLAST algorithm allows mismatches and gaps within the query sequence to produce a positive alignment.